REFERENCE PROJECT
WPD - South Devon

Thermal and Voltage Constraint Management

Constraint Manager

Core

Anchor 1

Project  Title : South Devon

Connecting DERs to SCADA / ANM
Thermal Constraint Management
Voltage Constraint Management
Demand Management
BESS (Battery Storage)
Network Security Management
Main System Functions

ANM - Level 3 / SCADA

ANM - Level 1 Controller

DER- Windfarm

User Case : DER Management integrating BESS (Storage)

Year : 2021

Anchor 3

Network Data
 
Generators - 74
Busbars - 1910

Circuits - 1937
Circuit Breakers - 1374
Transformers - 275

 

Project Statistics

 Includes 4 GSPs (11kV to 132kV) 

Max Demand = 1440 MW (Typically)

Anchor 4

Notable Features

Primary Benefits

Primary Project Features

Largest ANM System in Europe

Added Demand Control

Added Battery Control (BESS)

​

Primary System Benefits

Increased DER connection portfolio

Improved system reliability with first SD11 system compliance in UK

Improved system headroom.

Energy Market

Transmission

Distribution

DER

Consumer

City_1_0070.jpg

Level 4 - Enterprise

ZOOM_Main_Model_Level_3A_edited.jpg

Level 3 - Control Centre

Level 2 - Substation

Primary_Substation_GSP_External_v100.jpg

RTU

SCADA

ANM

Level_3_Control_Room_HD.png

Level 1 - Field

BESS_Control_v102.jpg

L1

DER 

L-1

DER 

Anchor 5

 

Modules Included in the Project

​

​

​

​

​

​

​

​

​

​

shutterstock_719950840.jpg

Main Functionality :

Thermal Constraint Manager
 

This module monitors for thermal and voltage violations in realtime. On detection of one or more network violations, DERs contributing to the violations are curtailed in order to resolve the problem. DERs can be constrained based upon user-defined Principles of Access (POAs). The ANM module can respond to both demand-led and generation-led constraints, and as such will respond appropriately to all types of DERs, including energy storage.

shutterstock_1612511572.jpg

Main Functionality :

Voltage Constraint Manager
 

Real time monitoring and management of voltage levels provides curtailment of DERs when voltage levels exceed user defined limits. Voltage control can be performed alongside thermal constraint management and the same levels of optimisation and PoA can be applied to the DERs. Limits can be user defined or determined by a Constraint Manager module.

Weather.jpg

Network Security - Ratings Management
 

Main Functionality :

This module must manage the network such that for a credible step change in prevailing demand and generation or securing for next fault the resulting net change in load shall not exceed a defined limit across all voltage levels and across all license areas unless explicitly agreed with the Transmission Operator. This is designed to limit the impact on the stability of the National System.

Project Process Flow

Thermal and Voltage

DER

SCADA / DMS System

Realtime

Anchor 6
Anchor 7
Anchor 2